EngiCalc
Engineering 2026

Engineering Formula & Sizing Suite

Comprehensive 22-tool engineering suite across electrical power, mechanical design, civil hydraulics, piping fluid dynamics, and live ambient psychrometrics.

ADVERTISEMENT
🔍
⚡ Ohm's Law & DC PowerFull View ↗
Electrical

Calculate electrical current (Amps) and electrical power dissipation (Watts) from Voltage & Resistance.

Current & Dissipated Power
5.00 A
Power (P = V × I): 1,150.00 W (1.15 kW)
🔌 Cable Voltage Drop CalculatorFull View ↗
Electrical

Calculates total voltage drop across one-way copper circuit distance and percentage loss (NEC ≤ 3% benchmark).

Voltage Drop & Loss
11.86 V (5.15%)
Load Voltage: 218.14 V (Recommend 4.0 mm² for < 3%)
🚥 4-Band Resistor Color CodeFull View ↗
Electrical

Decode 4-band through-hole resistor values with multiplier and tolerance rating.

Resistance Value
47.0 kΩ ±5%
Range: 44.65 kΩ - 49.35 kΩ
⚙️ Torque, RPM & Mechanical PowerFull View ↗
Mechanical

Shaft power and mechanical output calculation from rotational speed and torque in kW and HP.

Shaft Power Output
39.27 kW
Equivalent: 52.66 Horsepower (HP)
🔄 Gear Ratio & Output SpeedFull View ↗
Mechanical

Speed reduction or overdrive calculation based on tooth count of driver and driven gears.

Output Speed & Ratio
600 RPM
Gear Ratio: 3.00:1 (3x Torque Multiplication)
🚜 Hydraulic Cylinder ForceFull View ↗
Mechanical

Push (extension) and pull (retraction) tonnage force based on bore diameter and hydraulic pressure.

Extension Push Force
105.56 kN
Push: 10.76 Tons | Pull (Annular): 79.17 kN (8.07 T)
🏗️ Concrete Slab & Footing VolumeFull View ↗
Civil

Calculate slab cubic meters (m³) and standard 50 kg cement bags required (Nominal M20 1:1.5:3 mix).

Total Volume & Cement Estimate
7.50 m³
Approx. 62 Bags (50kg cement) for M20 Mix
📐 Simple Beam Center DeflectionFull View ↗
Civil

Calculates maximum deflection (δ = P·L³ / 48·E·I) of a simply supported beam with a center point load.

Maximum Center Deflection
6.73 mm
Deflection Ratio: L / 891 (Well within L/360 limit)
🌊 Reynolds Number & Flow RegimeFull View ↗
Fluids

Predicts flow regime inside pipes (Laminar Re < 2300, Transitional, or Turbulent Re > 4000).

Reynolds Number (Re)
74,701
Turbulent Flow (Re > 4000)
🔥 Thermal Conduction Heat LossFull View ↗
Thermal

Fourier's Law of Heat Conduction (Q = k · A · ΔT / d) for planar walls, building insulation, and heat exchangers.

Heat Transfer Rate
200.0 W
R-Value: 2.50 m²·K/W | Daily Loss: 4.80 kWh
💨 Pneumatic Air ConsumptionFull View ↗
Mechanical

Compressed air requirement for reciprocating cylinders to properly size factory air compressors.

Free Air Delivered (FAD)
55.0 L/min
Equivalent: 1.94 SCFM
⚡ 3-Phase AC Motor Current (FLA)Full View ↗
Electrical

Calculates running full load amps (FLA), starting inrush current, and breaker sizing.

Full Load Running Current (FLA)
26.96 A
Starting Current (6×): ~161.8 A | Suggested Breaker: 32 A
🚰 Darcy-Weisbach Pipe Head LossFull View ↗
Fluids & Thermal

Calculates friction head loss (m) and pressure drop (bar) in closed piping systems.

Head Loss & Pressure Drop
3.42 m Head Loss
ΔP: 0.335 bar (33.5 kPa) | Fluid Velocity: 1.38 m/s
❄️ HVAC Airflow & Cooling Load (CFM)Full View ↗
Mechanical

Converts airflow CFM and temperature differential into cooling tonnage (TR) and kW.

Cooling Capacity & Tonnage
3.24 TR (Tons)
Sensible: 25,920 BTU/h | Total: 37,029 BTU/h (10.85 kW)
🔩 Bolt Tightening Torque & PreloadFull View ↗
Mechanical

Calculates target tightening torque (N·m) and clamp preload force based on ISO 898 bolt grades.

Recommended Tightening Torque
68.3 N·m
Clamp Preload Force: 37.9 kN (8,527 lbf) | 50.4 ft·lb
🌡️ Thermal Expansion SizingFull View ↗
Civil & Structures

Computes linear thermal expansion (ΔL) for bridge joints, railway rails, and piping loops.

Thermal Expansion (ΔL)
24.00 mm
Temp Differential (ΔT): 40 °C | Minimum Gap Clearance: 24 mm
🔄 Centrifugal Pump Head (TDH) & PowerFull View ↗
Fluids & Thermal

Determines pump Total Dynamic Head (m) and required shaft motor power in kW.

Total Dynamic Head & Shaft Power
34.50 m Head
Hydraulic Power: 2.82 kW | Required Motor Power: 3.92 kW (5.25 HP)
🌀 Helical Compression Spring SizingFull View ↗
Mechanical

Computes spring rate (stiffness k), solid height, and Wahl shear stress correction factor.

Spring Stiffness & Deflection
8.49 N/mm
Deflection under 250 N: 29.4 mm | Wahl Stress Factor Kw: 1.18
🏞️ Manning's Open Channel Water FlowFull View ↗
Civil & Structures

Sizes culverts, open rectangular drainage flumes, and stormwater channels.

Discharge Capacity (Q)
2.18 m³/s (2,178 L/s)
Mean Velocity: 1.81 m/s | Hydraulic Radius: 0.387 m
🛡️ ASME Pressure Vessel Shell SizingFull View ↗
Mechanical

Computes minimum cylindrical shell wall thickness according to ASME Sec VIII Div 1.

Minimum Required Shell Thickness
11.26 mm
Pressure Thickness: 8.26 mm + 3.0 mm Corrosion | Standard Plate: 12 mm
🏗️ Cantilever Beam Deflection & StressFull View ↗
Civil & Structures

Sizes tip deflection (mm) and maximum root bending stress for end-loaded cantilever beams.

Tip Deflection & Max Moment
11.57 mm
Max Bending Moment: 20.0 kN·m | Deflection Ratio: L / 216
🌍 Live Ambient Air Density & BarometerFull View ↗
Fluids & Thermal

Fetches live meteorological surface pressure & temperature via Open-Meteo to calculate air density (ρ) and speed of sound.

🟢 Open-Meteo Live
Computed Air Density (ρ) & Sound Velocity
1.184 kg/m³
Speed of Sound: 346.2 m/s | Surface P: 1,013.2 hPa | Temp: 25.0°C